EasyManuals Logo

Siemens MCP 398C Diagnostics Guide

Siemens MCP 398C
1002 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #943 background imageLoading...
Page #943 background image
08/2005 Overview of Alarms
2-943
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Program Con-
tinuation:
Internal
400264 Pointer parameter machine control panel 1 incorrect
Definitions: A pointer is incorrect in the MCP1 parameter range.
Reactions: - Alarm display.
Remedy: Correct the PLC configuration in the FB1 parameters.
Program Con-
tinuation:
Switch control OFF - ON.
400265 Pointer parameter machine control panel 2 incorrect
Definitions: A pointer is incorrect in the MCP 2 parameter range.
Reactions: - Alarm display.
Remedy: Correct the PLC configuration in the FB1 parameters.
Program Con-
tinuation:
Switch control OFF - ON.
400266 Pointer parameter handheld unit incorrect
Definitions: A pointer is incorrect in the HHU parameter range.
Reactions: - Alarm display.
Remedy: Correct the PLC configuration in the FB1 parameters.
Program Con-
tinuation:
Switch control OFF - ON.
400267 Access error
Definitions: MCP or HHU data could not be accessed
Reactions: - Alarm display.
Remedy: Check the MCP or HHU parameters of the FB1.
Program Con-
tinuation:
Switch control OFF - ON.
400604 Set change with M06 in the machine data
Definitions: With the magazine type used (box magazine, chain), changing is possible only with M06.
If necessary, also check for impermissible settings at revolver magazines.
Reactions: - Alarm display.
Remedy: Set the value in the channel-specific machine data TOOL_CHANGE_MODE (MD 22550)
to 1.
Program Con-
tinuation:
Internal
400902 Parameter ChanNo impermissible in FC 9
Definitions: The parameterized channel does not exist.
Reactions: - Alarm display.
Remedy: Correct the parameter.
Program Con-
tinuation:
Switch control OFF - ON.
400903 Parameter IntNo impermissible in FC 9
Definitions: The parameterized interrupt does not exist.
Reactions: - Alarm display.
Remedy: Correct the parameter.

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals