Connecting
7.2 Safety information for wiring
NCU 7x0.3 PN
Manual, 09/2011, 6FC5397-1EP40-0BA0
43
Interface overview
Table 7- 1 Overview of available external interfaces
Interface Designation Connector type
DRIVE-CLiQ X100 - X105 Spec. RJ45 socket
Ethernet IE1/OP X120 Standard RJ45 socket
Ethernet IE2/NET X130 Standard RJ45 socket
Ethernet (service socket) X127 Standard RJ45 socket
PROFINET X150; ports 1, 2 Standard RJ45 socket
Digital inputs/outputs X122, X132, X142 Screw terminals, 3x14 pin
24 V power supply X124 Screw terminals, 4-pin
USB X125, X135 USB socket
PROFIBUS DP1 X126 9-pin SUB-D socket
PROFIBUS DP2/MPI X136 9-pin SUB-D socket
RS232 (service socket) X140 9-pin SUB D plug connector
Measuring sockets (T0, T1, T2,
and M)
X141, X143 Sockets on the printed-circuit board
CompactFlash Card X109 50-pin socket
Dual fan/battery module X190 6-pin
7.2 Safety information for wiring
Note the following:
Safety information
DANGER
The system power supply must be disconnected when you wire the control unit.
NOTICE
If your axis grouping contains a Smart Line Module without DRIVE-CliQ (5 kW or 10 kW),
you must assign the Smart Line Module enable signal to digital output X122.1 on the
control unit.