Siemens AG
A6V10424353_b
Building Technologies 2017-11-27
Technical data
Power supply
Operating voltage AC 230 V
Switching voltage AC 12…240 V
Frequency 50 Hz
Power consumption 50 mA
Backup battery Type CR2032 lithium battery
Life Min. 3 years
Max. external supply line fusing: 3 A
Outputs
Contact rating - Resistive: max. 6 A
- Inductive: max. 2 A
Environmental conditions
Moisture and dust ingress IP30
Operating humidity 20…80% r.h., 90% r.h. non-condensing
Operating ambient temperature 0...50
Storage ambient temperature -20...60
Standards, directives and approvals
EU conformity (CE) 8000078260
*)
Safety class as EN60730-2-7 standard
Housing as IEC 730 standard
Environmental compatibility
The product environmental declaration (A6V101118376 )
contains data on environmentally compatible product
design and assessments (RoHS compliance, materials
composition, packaging, environmental benefit, disposal).
*
)
The documents can be downloaded from http://siemens.com/bt/download.
General
Connection terminals 2.0 mm dia.
Housing Fire retardant, ABS material
Weight without/with packaging 289 g/332.5 g