page 6 of 7
Command Function (default values in
bold type )
Implementation comments Reference
\N6 No action
\Q[n] Local flow control selection
(DTE ↔ DCE)
customisable
\Q0 Disable flow control
\Q1 XON-XOFF software flow
control
\Q2 CTS only flow control
\Q3 RTS/CTS flow control
\S Display monitored variables DNT
\V[n} n = 0 No /REL or /RLP
appendix with the ‘connect’
message
n = 1 /REL or /RLP
appendix with the ‘connect’
message
DNT
%An No action
%C No action
%C1 No action
%Dn No action
^S... Routed to MS See gsatxsie.c. DNT, Siemens