When installing the device, keep to the safety notices listed below. 
 
If a device is operated in an ambient temperature of more than 50 °C, the temperature of 
the device housing may be higher than 70 °C. The device must therefore be installed so 
that it is only accessible to service personnel or users that are aware of the reason for 
restricted access and the required safety measures at an ambient temperature higher than 
50 °C. 
Safety notices on use in hazardous areas 
General safety notices relating to protection against explosion 
 
The device may only be operated in an environment with pollution degree 1 or 2 (see IEC 
60664-1). 
 
When used in hazardous environments corresponding to Class I, Division 2 or Class I, 
Zone 2, the device must be installed in a cabinet or a suitable enclosure. 
General notes on use according to ATEX and IECEx 
 
To comply with EC Directive 94/9 (ATEX95) or the conditions of IECEx, this enclosure or 
cabinet must meet the requirements of at least IP54 in compliance with EN 60529.