3 Engineering VRRP
VRRP
Entry-ID: 109798556, V1.0, 09/2021
41
© Siemens AG
2021 All rights reserved
4. Leave the "Master" function unticked.
The reason for this is that when the master is named explicitly, its IP address is
also automatically entered as the Associated IP Address. This is not desired
here, as the VRRP partners should respond to a third, virtual IP address.
5. Leave the "Advertisement Interval" at one second (10 cs = 1 s).
6. Check the box for "Preempt lower priority master".
This ensures that, if a master returns, it will reassume the master role.
7. Click the "Set Values" button.
8. Now select vlan20/ 20 in the same dialog under "Interface / VRID" and enter
the values as shown in the image below.
9. Click the "Set Values" button and close the dialog.