Siemens SIMATIC Ident - System Requirements and Notices; Error and system messages

Siemens SIMATIC Ident
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SIMATIC MV420/SIMATIC MV440
A5E02370910-06, 04/2013
5
Pinout of Power IO RS-232 cable
NOTICE
INPUT - COMMON or OUTPUT - COMMON must be connected
To be able to use the inputs and outputs described below, it is imperative that the INPUT - COMMON or OUTPUT -
COMMON is connected.
Table 3-1 SIMATIC MV440
Pin Color Signal name Possible values Default setting Meaning
H red 24 V DC Power supply
G blue 0 V Power supply
K violet INPUT1 TRG TRG Trigger input
D yellow INPUT /
OUTPUT2
DISA, SEL0, SEL1, SEL2, SEL3, TRN,
RES, IN_OP, TRD, RDY, READ,
MATCH, N_OK, EXT_1, EXT_2,
EXT_3, EXT_4
IN_OP Freely selectable input
or output.
L Gray/
pink
INPUT /
OUTPUT3
DISA, SEL0, SEL1, SEL2, SEL3, TRN,
RES, IN_OP, TRD, RDY, READ,
MATCH, N_OK, EXT_1, EXT_2,
EXT_3, EXT_4
RDY Freely selectable input
or output.
C green INPUT /
OUTPUT4
DISA, SEL0, SEL1, SEL2, SEL3, TRN,
RES, IN_OP, TRD, RDY, READ,
MATCH, N_OK, EXT_1, EXT_2,
EXT_3, EXT_4
READ Freely selectable input
or output.
B brown INPUT /
OUTPUT5
DISA, SEL0, SEL1, SEL2, SEL3, TRN,
RES, IN_OP, TRD, RDY, READ,
MATCH, N_OK, EXT_1, EXT_2,
EXT_3, EXT_4
N_OK Freely selectable input
or output.
A white INPUT -
COMMON
Reference point, 0 V or
24 V for inputs.
E gray OUTPUT -
COMMON
P-type inputs/outputs:
INPUT - COMMON = 0 V and
OUTPUT - COMMON = + 24 V DC
N-type inputs/outputs:
INPUT - COMMON = + 24 V DC and
OUTPUT - COMMON = 0 V
Reference point, 0 V or
24 V for outputs.
J black STROBE
(OUTPUT)
Signal output for
connecting external
strobe lights
F pink RS-232 TXD RS-232 send line
M red/blue RS-232 RXD RS-232 receive line

Other manuals for Siemens SIMATIC Ident