Siemens Acuson S1000 User Manual

Siemens Acuson S1000
518 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Siemens Medical Solutions USA, Inc. 11286694-ABS-001-01-01
ACUSON S1000
ACUSON S2000
ACUSON S3000
Diagnostic Ultrasound System
Instructions for Use

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens Acuson S1000 and is the answer not in the manual?

Siemens Acuson S1000 Specifications

General IconGeneral
TypeUltrasound System
ManufacturerSiemens Healthineers
ModelAcuson S1000
Power Requirements100-240 V AC, 50/60 Hz
Operating Temperature10°C to 40°C
ConnectivityDICOM, USB, Ethernet
DisplayHigh-resolution LCD
PortabilityCart-based
Storage Temperature-20°C to 60°C
Image ModesB-mode, M-mode, Color Doppler, Power Doppler, Pulsed Wave Doppler
ApplicationsGeneral Imaging, Cardiology, Vascular, Obstetrics, Gynecology
Humidity Range30% to 85% non-condensing
Transducer Frequency Range2-15 MHz (depending on transducer)

Summary

2 Safety and Care

Operating Safety and Environment

Covers essential safety considerations for operating the ultrasound system.

Electrical Safety

Details critical safety precautions related to the system's electrical components.

3 System Setup

Initial Setup

Explains the initial setup procedures for the ultrasound system.

System Startup

Guides users through the process of powering on and starting the ultrasound system.

4 Examination Fundamentals

Preventing Unauthorized Access

Explains how to secure the ultrasound system and protect patient information.

5 Transducer Accessories and Biopsy

Biopsy (Puncture) Guideline Function

Explains how to activate and use on-screen guidelines for biopsy procedures.

6 Transesophageal Transducer

Preventing Injury and Equipment Damage

Outlines preventive measures to ensure patient safety and protect equipment.

8 Physiologic Function

Activating the ECG Feature

Provides step-by-step instructions for activating the ECG feature.

9 eSieFusion Imaging

Activating and Deactivating eSieFusion

Details the procedures for activating and deactivating the eSieFusion feature.

Troubleshooting

Offers solutions for common issues encountered with the tracking system.

10 Virtual Touch Applications

Virtual Touch Imaging

Describes how to use Virtual Touch imaging to qualitatively visualize tissue stiffness.

Virtual Touch Quantification

Explains how to measure tissue shear velocity and elasticity quantitatively.

Virtual Touch IQ

Details how to quantitatively depict tissue stiffness and measure shear wave velocity.

Appendix B Control Panel and Touch Screen

Appendix E Advanced Feature Controls

Appendix F Acoustic Output Reference

Display Accuracy and Measurement Uncertainty

Explains the accuracy and uncertainty of displayed MI and TI values.

Default Displayed MI and TI Values by Transducer

Lists the default MI and TI values for various transducers and modes.

Track 3, FDA 510(k) and IEC 60601-2-37 Acoustic Output Reporting

Presents acoustic output data according to regulatory standards for specific transducer/mode combinations.

Summary Table for Acoustic Output

Provides a summary table indicating MI or TI indices exceeding 1.0 for transducer/modes.

Related product manuals