SIMATIC MV420/SIMATIC MV440
A5E02370910-06, 04/2013
7
ASM cable
The connectors are already fitted to the ASM cable.
You connect the communication modules, for example RF180C and ASM456, using the ASM cable.
For SIMATIC MV420, a special ASM cable with M16 socket is available.
The follow cable assignment is defined for connecting to the ASM 475 module:
6
6
(
(
6
6
(
(
$60
6)
'&9
$&7B
(55B
35(B
5['B
$&7B
(55B
35(B
5['B
02%<
*7*$
6/*6/*

Status and error displays
Connection diagram; the numbers of the connection relate to the X1 connector on the top of the housing
Figure 3-2 Front cover and inside of the front door of the ASM 475 module
Pin M16 socket Wire color of the connecting cable Connection terminal ASM475 (channel 1/channel 2)
H Red 8 / 16
G Blue 9 / 17
F Pink 4 / 12
M Red/blue 5 / 13
B Brown 6 / 14
C Green 7 / 15
Ethernet cable M12/RJ-45
With a preassembled Ethernet cable, you connect a PC/PG to control and operate the reader.
Connect the Ethernet cable to a switch to link the reader to an automation system via onboard PROFINET IO.