SIMATIC IPC477E 1900 PRO HD LR Ext.
A5E44290044-AA, 03/2018
21
Technical specifications of the IPC1900 PRO HD LR Ext.
Weight per PRO device:
19" display pedestal or support arm
8.2 kg
Power supply
1
24 V DC (-20 % / +20 %)
1
Short-term voltage interruption according to Namur
Min. 20 ms at 20.4 V (DC)
Degree of protection
IP 65 (all-round)
Enclosure Type 4X / 12 (indoor use only)
Quality assurance
In accordance with ISO 9001
Operating system Windows 7 Ultimate (32-/64-bit)
1
The device may only be connected to a 24 V DC power supply that meets the requirements of a safe extra-low voltage
(SELV) according to IEC/EN/DIN EN/UL 60950-1.
Power consumption (DC)
The following figure shows the maximum power consumption of the PRO device:
Device type
19" Touch
78 W
The values are determined under the following test conditions:
24 V DC supply voltage
Internal storage media:
One SSD
A CFast card
External storage media: 4 x USB 3.0, maximum 1 high-current
3 active LAN interfaces
BIOS setting: High Performance
"Dim" setting with SetBrightness dialog: 99 (9 ... 99 ≙ 10 ... 100%)
Motherboard
The device has the following components:
Processor
Intel® Core™ i5-6442EQ Processor (6 MB cache, up to 2.7 GHz)
Main memory Memory modules without ECC:
8 GB DDR4-SDRAM SODIMM
Backup memory 512 KB NVRAM
Drive and memory media
Solid State Drive
1 × 240 GB; 2.5" SATA-SSD
Display
19"
Display type
LCD TFT
Active display area
410 x 230 mm
Resolution 1366 x 768 pixels
Possible colors
Up to 16.7 million
Brightness control Yes, value range 0 to 99 0 = backlighting off
Backlighting
Half Brightness Life Time (MTBF
1
)
LED
50000 h
Pixel error class in accordance with ISO 9241-307 II
1
MTBF: Operating hours after which the maximum brightness is reduced by half compared to the original value. MTBF is
increased by using the integrated dimming function, for example time-controlled via screen saver or centrally via
PROFIenergy.