Technical Specifications
5.5Operating Environment
Mode
Connector
Type
Cable
Type
(μm)
Tx λ
(nm)
a
Tx min
(dBm)
Tx max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(km)
a
MM LC 50μ/125 850 -9.5 -4 -20 0 0.5
SM LC 9μ/125 1310 -9.5 -3 -22 -3 10
SM LC 9μ/125 1310 -5 0 -22 -3 25
SM SC 9μ/125 1310 -10 -3 -22 -3 10
SM SC 9μ/125 1310 -7 -3 -24 -3 25
a
Typical.
5.5 Operating Environment
The RUGGEDCOM RS900G is rated to operate under the following environmental
conditions.
Ambient Operating
Temperature
ab
-40 to 85 °C (-40 to 185 °F)
Ambient Storage
Temperature
-40 to 85 °C (-40 to 185 °F)
Ambient Relative
Humidity
c
5% to 95%
Maximum Altitude
d
2000 m (6562 ft)
a
Measured from a 30 cm (12 in) radius surrounding the center of the RUGGEDCOM RS900G enclosure.
b
Operating temperature may vary based on the limitations of installed SFPs. Refer to the RUGGEDCOM
SFP Transceivers Catalog for SFP temperature ratings.
c
Non-condensing
d
Over temperature range of -40 to 85 °C (-40 to 185 °F)
5.6 Mechanical Specifications
Weight 1.2 kg (2.7 lbs)
Ingress Protection IP30
Enclosure 20 AWG Galvanized Steel
5.7 Dimension Drawings
Note
All dimensions are in millimeters, unless otherwise stated.
RUGGEDCOM RS900G
Installation Manual, 01/2021, C79000-G8976-1025-08
25