Configuring with Web Based Management
6.3 "Wizard" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
99
●
Specify whether or not the device can be accessed with DCP (Discovery and
Configuration Protocol):
– "-" (disabled)
DCP is disabled. Device parameters can neither be read nor modified.
– Read/Write
With DCP, device parameters can be both read and modified.
– Read Only
With DCP, device parameters can be read but cannot be modified.
●
Select the protocol from the drop-down list. The following settings are possible:
– "-" (SNMP disabled)
Access to device parameters via SNMP is not possible.
– SNMPv1/v2c/v3
Access to device parameters is possible with SNMP versions 1, 2c or 3. You can
configure other settings in "System > SNMP > General".
– SNMPv3
Access to device parameters is possible with SNMP version 3. You can configure
other settings in " System > SNMP > General".
●
Enable or disable write access to SNMP variables with SNMPv1/v2c.
●
SINEMA configuration interface
If the SINEMA configuration interface is enabled, you can download configurations to the
device via the TIA Portal.