Configuring with Web Based Management
6.3 "Wizard" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
99
DCP Server
Specify whether or not the device can be accessed with DCP (Discovery and
Configuration Protocol):
"-" (disabled)
DCP is disabled. Device parameters can neither be read nor modified.
Read/Write
With DCP, device parameters can be both read and modified.
Read Only
With DCP, device parameters can be read but cannot be modified.
SNMP
Select the protocol from the drop-down list. The following settings are possible:
"-" (SNMP disabled)
Access to device parameters via SNMP is not possible.
SNMPv1/v2c/v3
Access to device parameters is possible with SNMP versions 1, 2c or 3. You can
configure other settings in "System > SNMP > General".
SNMPv3
Access to device parameters is possible with SNMP version 3. You can configure
other settings in " System > SNMP > General".
SNMPv1/v2 Read-Only
Enable or disable write access to SNMP variables with SNMPv1/v2c.
SINEMA configuration interface
If the SINEMA configuration interface is enabled, you can download configurations to the
device via the TIA Portal.

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE W700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W700 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W700 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W700
CategoryWireless Access Point
LanguageEnglish

Related product manuals