The table below shows how the MAC addresses are assigned.
Table 4-2Assignment of the MAC addresses
Assignment Labeling
MAC address 1 PROFINET interface X1
(visible in STEP7 in accessible devices)
Front, lasered
Right side, lasered
(start of number range)
MAC address 2 Port X1P1R (required for LLDP, for
example)
Front and right side, not lasered
MAC address 3 Port X1P2R (required for LLDP, for
example)
Front, not lasered
Right side, lasered
(end of number range)
Block diagram
The following figure shows the block diagram of the CPU 1511-1 PN.
3
4
2
5
1
L+
M
X50
X1 P1
PN
X1 P1R
X1 P2
R/S ER MT
PN
X1 P2R
X80 DC 24 V
SA
CPU with control and operating mode
buttons
X80 24 V DC Infeed of supply voltage
Electronics L+ 24 V DC supply voltage
PROFINET 2-port switch M Ground