Using the SSI_Absolute_Encoder technology object
4.4 Configuring SSI_Absolute_Encoder
Counting, measurement and position detection
Function Manual, 12/2017, A5E32009889-AG
155
Position value
The position value supplied in Gray code is converted into binary code by the technology
module and returned right-justified in the feedback interface: The special bits are ignored in
this case. The parity bit is evaluated but is not returned with the position value: