What to do after filling a pipe with Siemens SITRANS F Measuring Instruments?
- VvanessamooreSep 23, 2025
After filling the pipe when using Siemens Measuring Instruments, press [ENT].









What to do after filling a pipe with Siemens SITRANS F Measuring Instruments?
After filling the pipe when using Siemens Measuring Instruments, press [ENT].
What to do if Siemens Measuring Instruments show 'Invalid Setup (use Direct Mount)'?
If your Siemens Measuring Instruments display 'Invalid Setup (use Direct Mount)', and selecting Direct Mode doesn't fix it, check all site setup and transducer installation choices. Pay close attention to the data entered for the pipe and liquid.
What to do if Siemens Measuring Instruments show ' Empty Pipe - Press [ENT]'?
If the Siemens Measuring Instruments display ' Empty Pipe - Press [ENT]', set up the Datalogger. You'll be prompted to empty the pipe during the Actual MTY procedure. After emptying the pipe, press .
What to do if Siemens SITRANS F Measuring Instruments show 'Fill Pipe - Press [ENT]'?
If your Siemens Measuring Instruments display 'Fill Pipe - Press [ENT]', it means you should press [ENT] after filling the pipe.
What to do if Siemens SITRANS F show 'Chan Not Setup'?
If your Siemens Measuring Instruments display 'Chan Not Setup', enable the channel [Channel Setup Channel Enable Yes]. Remember, a channel can't be enabled until its transducers are operating.
What to do after emptying a pipe with Siemens Measuring Instruments?
After emptying a pipe when using Siemens Measuring Instruments, press .
What to do if Siemens SITRANS F displays 'Memory Full!'?
If your Siemens Measuring Instruments displays 'Memory Full!', delete an obsolete site or clear the Datalogger memory to make room for new data.
What to do if Siemens Measuring Instruments displays 'Memory Corrupted! Chan Not Setup'?
If Siemens Measuring Instruments displays 'Memory Corrupted! Chan Not Setup', it means a memory read error occurred while accessing the active site data. Enable the channel [Channel Setup Î Channel Enable Î Yes]. Note that a channel cannot be enabled until its transducers are operating.
What does failure mean on Siemens Measuring Instruments?
A 'Failure' indication on your Siemens Measuring Instruments means that the output signal is invalid.
What happens if Siemens Measuring Instruments are out of specification?
If your Siemens Measuring Instruments are 'Out of specification', the device will still work, but output signals may be invalid.
| Type | Electromagnetic Flow Meter |
|---|---|
| Accuracy | ±0.2% of measured value |
| Nominal Diameter | DN 2 to DN 3000 |
| Output | 4-20 mA, Pulse, HART, PROFIBUS PA/DP, Foundation Fieldbus |
| Power Supply | 24 V DC |
| Protection Class | IP67, IP68 |
| Housing Material | Aluminum, Stainless Steel |
| Lining Material | PTFE, PFA, Hard Rubber |
| Electrode Material | Stainless Steel, Hastelloy, Platinum, Tantalum |
Crucial safety guidelines and recommendations for experienced personnel during installation and operation.
Provides a step-by-step procedure for the typical installation of the energy meter.
Guide to accessing, navigating, and entering data within the Installation Menu.
Menu for managing site setups, including creating, recalling, deleting, and saving sites.
Allows definition of application pipe parameters like class, size, material, and thickness.
Menu to edit default settings matching the application, including liquid properties.
Guides transducer selection, mounting mode, and spacing based on pipe and application data.
Preliminary steps before mounting transducers, including location selection and pipe preparation.
Guidelines for installing temperature sensors for accurate differential measurement.
Guidance on contacting Siemens for technical assistance and utilizing diagnostic data.
Information on pipe materials, dimensions, and their impact on clamp-on transducer performance.
Step-by-step guide for setting up the FUE1010EN for flow tube operation.
Details two mounting configurations: Adjacent and In-Line for Reflexor mode.
Procedure to access the menu for transducer selection and installation.
Tool for determining installation adequacy and adjusting application-dependent parameters.