4-15
1010ENFM-3B
Section 4
To enable (or disable) Line Feed:
To access the [Line Feed] option list press
Use to move the asterisk to [Yes] Line feed enabled, or [No] Line feed disabled.
To store the data press . This moves the cursor to Network ID.
4.8.5 NETWORK ID
The Network ID menu cell stores an identification number to facilitate host computer polling when you
use this system in a network environment. The Network ID number can be any value other than 0 (zero).
The default setting, zero, disables the network function. Note that entering a non-zero Network ID num-
ber suspends all routine Datalogger activity regardless of any selected options.
NOTE: If you are using the flowmeter for a “stand-alone” application, you must keep the zero
Network ID number.
To assign a Network ID number
To enable numeric entry press
Use the numeric keys to type the Network ID number.
To store Network ID press . This moves the cursor to RTS Key Time.
4.8.6 RTS KEY TIME
During a serial transmission session, you can select how long the flow computer holds its request-to-
send line high until it receives a clear-to-send signal. If the RTS key time expires the FUE1010EN returns
its RTS line low aborting the transmission attempt. Data entry units are seconds. The default RTS key time
is 0.2 seconds.
NOTE: The RTS Key Time function is only provided when the meter’s Network ID number is non-
zero.
To set the RTS Key Time:
To access the [RTS Key Time] option list press
To move the asterisk to the required RTS time press
To store the data press
ENT
ENT
ENT