2.11.9 TROUBLESHOOTING TIPS
The FUE1010EN has highly reliable circuitry and will provide trouble-free operation within specified en-
vironments. Even a well-crafted precision instrument can fail if exposed to extreme temperature or
vibration conditions during service, storage or transportation. The Diagnostic menu shows how the sys-
tem interprets a problem. The test functions and alarm indicators identify “hidden” problems automati-
cally. If a problem seems unsolvable, call our Technical Service Department or your local Siemens Rep-
resentative for expert help.
Flow Computer Messages
Certain actions or conditions invoke messages that may appear as a pop-up window, in the right-hand
column of a given menu cell, or the highlighted prompt line at the top of the display screen. The following
is a list of messages that you may encounter along with explan-ations, and in some cases, a recom-
mended action.
MESSAGE DESCRIPTION
Memory Full! Response to an attempt to save site data, when data memory is full. Delete
an obsolete site or clear Datalogger memory to make room for the new data.
Memory Corrupted! Memory read error occurred while accessing the active site data.
Chan Not Setup Response to an attempt to invoke an operation that requires a channel to
be enabled. Enable the channel [Channel Setup Channel Enable Yes].
Note that a channel cannot be enabled until its transducers are operating.
Clr All Data? Response to pressing the F4 key. Use the F4 function to restore operation if
a severe event (e.g., a violent power surge) disrupts system operation.
Clr Dynamic Memory? Response to pressing the F4 key, then selecting [No] for Clr All Data?
<EOT> Response to a request to output datalogger data to the printer or the
Graphics screen when no datalogger data exists. Set up the Datalogger.
Empty Pipe - Press [ENT] Prompt to empty the pipe during the Actual MTY procedure. After emptying
pipe, press <ENT>.
Fill Pipe - Press [ENT] Prompt to fill the pipe during the Actual MTY procedure. After filling the pipe,
press [ENT] (see paragraph 3.1.3).
No Sites Response while trying to recall/delete a site setup when no Sites are stored.
Not Installed Response to an attempt to access a menu function that is not included.
Re-space Index Upon measuring the liquid sonic velocity (Vs), the meter recommends re-
spacing the transducers to improve performance.
Invalid Setup During the Initial Makeup, the system detects invalid transducer spacing,
erroneous liquid/pipe parameters, or some other factor that prevents it
from completing the Initial Makeup. This may be due to one of the following:
• An out-of-range data entry.
• An invalid condition; (e.g., overlapping transducers in Reflect Mode). If se-
lecting Direct Mode does not resolve, review all site setup and transducer
installation choices; particularly data entered for the pipe and liquid.
• In Reflect Mode, the flow computer detects that the pipe wall signal may
infringe upon the liquid signal. Use Direct Mode instead.
Press <ENT>, <UP Arrow>, <DOWN Arrow>, or <LEFT Arrow> to abort install
routine. Continue programming other site data in anticipation of resolving the
difficulty later. Call technical support for help if necessary.
(use Direct Mount)