2.2.1 HOW TO SELECT A PIPE CLASS
The FUE1010EN pipe tables are arranged by classes of common type and material. The default selection
is [Manual Entry]. As its name infers, you would use this selection to manually enter individual pipe
parameters.
To select a Pipe Class:
To access the [Pipe Class] option list press
To scroll through the available classes press
To select the class that fits your application press
When you pick a Pipe Class, the Select Pipe Size menu cell (see below) presents the pipe size option
list associated with the selected class. By using the pipe class and pipe size option lists, you automati-
cally load all the required pipe information. You can also select a pipe class/size, then edit any of the
associated defaults to fine-tune the pipe data.
NOTE: Create custom pipe data via the Pipe Table editor in the Meter Facilities menu.
2.2.2 HOW TO SELECT A PIPE SIZE
Selecting a Pipe Size installs the selected pipe parameters into the balance of the Pipe Data menu cells
and prepares the FUE1010EN for Transducer selection and Installation.
ENT
THE PIPE DATA MENU STRUCTURE (cont.)
Pipe Material Steel
ABS
Aluminum
Black Iron
Brass
Cast Iron
CuNi (70/50)
CuNi (90/10)
Copper
Ductile Iron
FRP
Glass
Hastelloy
Inconel
Kynar (PVDF)
Monel
Nickel
Polyethylene
PVC (Plastic)
Teflon
Titanium
Wall Thickness x.xxx (numeric entry)
Liner Material None
Cement
Coal Tar
Enamel
Glass
Plastic
HDPE
Teflon
Rubber
Liner Thickness x.xxx (numeric entry)