SITRANS F
Ultrasonic flowmeters
SITRANS FUS380/FUE380
Operating Instructions
7ME340 (FUS380)
7ME341 (FUE380)
05/2018
A5E00730100-AE
Introduction
1
Safety notes
2
Description
3
Installing/Mounting
4
Connecting
5
Commissioning
6
Functions
7
Service and maintenance
8
Troubleshooting/FAQs
9
Technical data
10
Parameter lists
A
Settings
B
Appendix A
C

Table of Contents

Questions and Answers

  • Z
    Zoe MartinAug 10, 2025
    What does F5 error mean on Siemens Measuring Instruments and how to fix it?
    • P
      Patrick SmithAug 10, 2025
      Error code F5 indicates that the battery charge is below the preset limitation. Replace the battery pack to resolve this issue.
  • V
    Virginia JacksonAug 15, 2025
    What does F3 error mean on Siemens Measuring Instruments?
    • O
      owenerikaAug 15, 2025
      Error code F3 indicates an internal software failure. Contact your supplier for assistance.
  • A
    Amanda JenkinsAug 20, 2025
    What does F4 error mean on Siemens Measuring Instruments?
    • S
      Steven MarshallAug 20, 2025
      Error code F4 indicates an internal software failure. Contact your supplier for assistance.
  • T
    Thomas HernandezAug 26, 2025
    What does F1 error mean on Siemens Measuring Instruments?
    • J
      Joshua WagnerAug 26, 2025
      Error code F1 indicates that there is no water in the upper part of the pipe and/or the cables or transducer 1A or 1B are defective.
  • B
    Billy DavisAug 30, 2025
    What does F2 error mean on Siemens Measuring Instruments?
    • L
      Lisa MurphyAug 30, 2025
      Error code F2 indicates that there is no water in the lower part of the pipe and/or the cables or transducers for 2A or 2B are defective.
  • R
    richardcoxSep 4, 2025
    What to do if Siemens Measuring Instruments display is blank?
    • A
      aaron79Sep 4, 2025
      If the display is blank, check the flowmeter version. Note that the battery version cannot run on mains power. Ensure the battery plug is connected, the battery is not empty, and the mains power is not interrupted. If you have a battery version, replace the battery pack.