3. Connect output cable to terminals 31, 32 and .
① Heat shrink tube
② Shield
③ 8.5 to 36 VDC
4. Tighten cable gland for current output cable (approx. 20 Nm).
5.5.3 Finishing connection
Mount the transmitter.
Note
Grounding
To ensure identical potential for sensor and transmitter, a direct grounding of transmitter and
sensor is recommended.
Note
Aligning the gasket
Please ensure that the gasket between terminal box and transmitter is well aligned before
tightening the screw (Min. torque 0.5 Nm).
5.6 Wiring energy calculator
An energy calculator is typically connected via the pulse output A (terminals 56 and 57) of the
transmitter.
For example, connection to the energy calculator SITRANS FUE950 can be found in the
operating instruction of the FUE950.
Connecting
5.6 Wiring energy calculator
SITRANS FUS380/FUE380
46 Operating Instructions, 05/2018, A5E00730100-AE