Note
The installation orientation of the battery pack may influence the battery capacity. Optimal
battery capacity is achieved with the battery pack in an upright position.
10.6 Sensor for FUS380 and FUE380
Table 10-6 Technical data
Description Specification
Pipe design 2-track sensor with flanges and integrated sensors wet-calibrated from fac‐
tory
Nominal size DN 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 500, 600, 700, 800,
900, 1000, 1200
Pressure rate PN 16, PN 25, PN 40
EN 1092-1 flanges:
type 01: DN 100 to DN 125
type 11: DN 150 to DN 1200
type 11 'design': DN 50 to DN 80
Pipe materials
DN 100 to 1200: Carbon Steel EN 1.0345 / p235 GH, painted in light gray
DN 50 to DN 80: Die-cast bronze G-CuAn 10/W2.1050.01 (EN1982)
Sensor design
DN 100 to 1200: Integrated version and welded onto the pipe
DN 50 to 80: Screwed into the pipe
Sensor material Stainless steel (AISI 316 / 1.4404) / brass (CuZn36Pb2As)
Medium temperature DN 100 to 1200:
Remote: 2 to 200 °C (35.6 to 392 °F)
1)
DN 50 to 80:
Remote: 2 to 150 °C (35.6 to 302 °F)
1)
DN 50 to 1200:
Compact: 2 to 120 °C (35.6 to 248 °F)
1)
Measured media Heating water, according to VDI-2035 (pH 8.2 - 10.5), industrial VdTÜV in‐
formation sheet 1466 and AGFW information sheet FW 510
1)
MID: minimum temperature 15 °C (59 °F)
Technical data
10.6 Sensor for FUS380 and FUE380
SITRANS FUS380/FUE380
Operating Instructions, 05/2018, A5E00730100-AE 93