Technical data
10
10.1 Accuracy
Typical accuracy SITRANS FUS380:
>IWV@
>PV@
>@
Figure 10-1 Accuracy SITRANS FUS380
± 0.5 % for 0.5 m/s < v < 10 m/s and ± 0.25 Ν
act.
[%] below 0.5 m/s
Typical accuracy SITRANS FUE380:
>IWV@
>PV@
>@
① FUE380 - Admissible limits according to EN 1434 class 2 and OIML R 75 class 2
Figure 10-2 Accuracy SITRANS FUE380
± (0.5 +0.02 Q
p
/Q) [%]
Q
p
according to EN 1434/OIML requirements
SITRANS FUE380 fulfills the requirements:
Ε
f
= ± (2 + 0.02 Q
p
/Q) max. ± 5 %, according to EN 1434 and OIML R 75, class 2 or MID class
2 requirements
SITRANS FUS380/FUE380
Operating Instructions, 05/2018, A5E00730100-AE 87