Parameter Default val‐
ue
Value range Access
level
Description
910 Fixed mode No No, Yes R/W Turn on/off fixed current
911 Fixed value 4 3 to 24 mA R/W Fixed current value on output
912 Alarm level 3.6 mA Off, 3.6 mA,
22.6 mA
R/W Selection of alarm level on current out in
case of alarm
A.3 Diagnostics
Table A-3 Diagnostic
Parameter Default val‐
ue
Value
range
Access
level
Description
Diagnostic
500 Latest service date 01-01-2000 dd-mm-
yyyy
R/W* Latest service date (can also be used for date
of installation)
501 Operating time 0 3.4E+38 h Read Total operation hours since last power up
503 Number of startups 0 0 to 65535 Read Total number of power-ups since first power-
up.
Alarm
200 Fault status One or
more of the
following
values: 1,
2, 3, 4, ... up
to 16
Read Fault status
1: Path 1 error
2: Path 2 error
3: Dual slope calibration error
4: Database checksum error
5: Low power warning
6: Flow overload warning
7: Pulse A overload warning
8: Pulse B overload warning
9: Consumption interval error
10: Leakage error (not used)
11: Hardware calibration error
12: Not used
13: Not used
14: Not used
15: Not used
16: Not used
202 Date of fault log reset Last reset
date
dd-mm-
yyyy,
hh:mm:ss
Read Date of last fault log reset
204 Reset the fault log and faults No No, Yes R/W Reset the fault log and faults
205 Call up acknowledge No No, Yes R/W Select "Yes" to reset active call-up
209 Reset consumption log fault No No, Yes R/W Reset the consumption fault.
Caused by too low or too high consumption in
the log interval
Parameter lists
A.3 Diagnostics
SITRANS FUS380/FUE380