5-7
1010ENFM-3B
Section 5
If you receive a [Memory Full!] message when you try to save a Site Setup, then you will have to delete
an obsolete Site Setup or clear the Datalogger Memory to make room. Another Datalogger memory
consideration applies to dual-channel systems, when both measurement channels are actively logging
data. Dual-channel meters store logged data from BOTH channels in a common file so you must include
Site ID for each line to identify the applicable measurement channel.
The FUE1010EN also offers a Memory Map and Defragmenting command in the Meter Facilities
area of the menu as an aid in visualizing and maximizing the efficient utilization of your flowmeter’s
memory resources.
5.6 REFERENCE TABLES
The following tables provide reference data that may be required during the Site Setup.
Liquids/Oils Vs(m/s) Liquids/Oils Vs(m/s)
Acetate, Butyl (n) 1270 Ethanol 1180
Acetate, Ethyl 1180 Ethylene Glycol 1620
Acetate, Methyl 1150 Gasoline 1250
Acetate. Propyl 1180 Glycerine 1920
Alcohol 1440 Linalool 1400
Alcohol, Butyl (n) 1270 Linseed Oil 1770
Alcohol, Ethyl 1180 Methylethyl Ketone 1210
Alcohol, Methyl 1120 Motor Oil (SAE 20/30) 1487
Alcohol, Propyl (i) 1170 Paraffin Oil 1420
Alcohol, Propyl (n) 1220 Pentane 1010
Benzene 1330 Petroleum 1290
Benzol, Ethyl 1340 Trichlorethylene 1050
Butyrate, Ethyl 1170 Transformer Oil 1390
Carbon Tetrachloride 938 Turpentine 1280
Diethyl Ketone 1310
SONIC VELOCITY (in meters/sec) FOR COMMON LIQUIDS @ 68
°F