What does failure mean on Siemens Measuring Instruments?
- WWalter WaltersSep 6, 2025
A 'Failure' indication on your Siemens Measuring Instruments means that the output signal is invalid.
 









What does failure mean on Siemens Measuring Instruments?
A 'Failure' indication on your Siemens Measuring Instruments means that the output signal is invalid.
What to do if Siemens SITRANS F Measuring Instruments show 'Memory Full!'?
If your Siemens Measuring Instruments display 'Memory Full!', you should delete an obsolete site or clear the Datalogger memory. This will free up space for new data.
What happens if Siemens Measuring Instruments are out of specification?
If your Siemens Measuring Instruments are 'Out of specification', the device will still work, but output signals may be invalid.
What does a process value warning mean on Siemens SITRANS F?
If your Siemens Measuring Instruments have a 'Process value warning', it means the process value has reached a warning limit.
What does 'Detection Fault' mean on Siemens SITRANS F?
A 'Detection Fault' on Siemens Measuring Instruments means that the pipe and/or liquid conditions do not permit a receive signal that meets the flow detection standards. To resolve this, attempt to improve operating conditions by reinstalling the transducers at a different spacing offset, or even at a different location on the pipe.
What does 'Invalid Setup (use Direct Mount)' mean on Siemens SITRANS F?
The 'Invalid Setup (use Direct Mount)' message on Siemens Measuring Instruments indicates that the system has detected invalid transducer spacing, erroneous liquid/pipe parameters, or some other factor preventing it from completing the Initial Makeup. If selecting Direct Mode doesn't resolve the issue, review all site setup and transducer installation choices, especially the data entered for the pipe and liquid.
What to do if Siemens SITRANS F show 'Clr All Data?'?
If a severe event disrupts the Siemens Measuring Instruments operation and 'Clr All Data?' is displayed, use the F4 function to restore operation.
What to do if Siemens SITRANS F show 'Chan Not Setup'?
If your Siemens Measuring Instruments display 'Chan Not Setup', enable the channel [Channel Setup Channel Enable Yes]. Remember, a channel can't be enabled until its transducers are operating.
What to do if Siemens SITRANS F Measuring Instruments show 'Fill Pipe - Press [ENT]'?
If your Siemens Measuring Instruments display 'Fill Pipe - Press [ENT]', it means you should press [ENT] after filling the pipe.
What to do if Siemens Measuring Instruments show ' Empty Pipe - Press [ENT]'?
If the Siemens Measuring Instruments display ' Empty Pipe - Press [ENT]', set up the Datalogger. You'll be prompted to empty the pipe during the Actual MTY procedure. After emptying the pipe, press .
| Type | Electromagnetic Flow Meter | 
|---|---|
| Accuracy | ±0.2% of measured value | 
| Nominal Diameter | DN 2 to DN 3000 | 
| Output | 4-20 mA, Pulse, HART, PROFIBUS PA/DP, Foundation Fieldbus | 
| Power Supply | 24 V DC | 
| Protection Class | IP67, IP68 | 
| Housing Material | Aluminum, Stainless Steel | 
| Lining Material | PTFE, PFA, Hard Rubber | 
| Electrode Material | Stainless Steel, Hastelloy, Platinum, Tantalum | 
Crucial safety guidelines and recommendations for experienced personnel during installation and operation.
Provides a step-by-step procedure for the typical installation of the energy meter.
Guide to accessing, navigating, and entering data within the Installation Menu.
Menu for managing site setups, including creating, recalling, deleting, and saving sites.
Allows definition of application pipe parameters like class, size, material, and thickness.
Menu to edit default settings matching the application, including liquid properties.
Guides transducer selection, mounting mode, and spacing based on pipe and application data.
Preliminary steps before mounting transducers, including location selection and pipe preparation.
Guidelines for installing temperature sensors for accurate differential measurement.
Guidance on contacting Siemens for technical assistance and utilizing diagnostic data.
Information on pipe materials, dimensions, and their impact on clamp-on transducer performance.
Step-by-step guide for setting up the FUE1010EN for flow tube operation.
Details two mounting configurations: Adjacent and In-Line for Reflexor mode.
Procedure to access the menu for transducer selection and installation.
Tool for determining installation adequacy and adjusting application-dependent parameters.