02.00 Parameter list
SIEMENS AG 6RX1700-0AD76 11-53
SIMOREG DC Master Operating Instructions
PNU Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
P614
*
Source for variable field current setpoint lower limit
Limitation at EMF controller output
Selection of connector to be injected as the variable field current setpoint
lower limit
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 4
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
P615
*
Source for EMF controller setpoint
Selection of connectors to be injected as the EMF controller setpoint. The
connectors selected in the four indices are added.
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 4
FS=
i001: 289
i002: 0
i003: 0
i004: 0
Type: L2
P052 = 3
P051 = 40
Offline
P616
*
Source for actual EMF controller value
Selection of connector to be injected as the actual EMF controller value
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=286
Type: L2
P052 = 3
P051 = 40
Offline
Configuring of injection of acceleration value
P619
*
Source for acceleration injection value
Selection of connector to be applied as the acceleration injection value
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=191
Type: L2
P052 = 3
P051 = 40
Offline
Speed controller
Speed controller, setpoint/actual value deviation
Function: The connectors selected in parameters P621 and P622 are added and those selected in P623 and 624 subtracted
P620
*
Source for speed controller setpoint/actual value deviation
Selection of connector to be injected as the control deviation
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=165
Type: L2
P052 = 3
P051 = 40
Offline
P621
*
Source for speed controller setpoint
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=176
Type: L2
P052 = 3
P051 = 40
Offline
P622
*
Source for speed controller setpoint
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=174
Type: L2
P052 = 3
P051 = 40
Offline
P623
*
Source for actual speed controller value
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=179
Type: L2
P052 = 3
P051 = 40
Offline
P624
*
Source for actual speed controller value
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline