Parameter list 02.00
11-54 SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
Speed controller: Filtering of setpoint and actual value, band-stop filters
P625
*
FDS
Source for speed controller setpoint
Selection of connector to be injected as the input signal for speed setpoint
filtering
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 4
FS=170
Type: L2
P052 = 3
P051 = 40
Offline
P626
*
FDS
Source for actual speed controller value
Selection of connector to be injected as the input signal for actual speed
value filtering
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 4
FS=167
Type: L2
P052 = 3
P051 = 40
Offline
P627
*
Source for input of D element
Selection of connector to be injected as the input signal for the D element
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=178
Type: L2
P052 = 3
P051 = 40
Offline
P628
*
Source for input of band-stop filter 1
Selection of connector to be injected as the input signal for band-stop filter
1
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=179
Type: L2
P052 = 3
P051 = 40
Offline
P629
*
Source for band-stop filter 2
Selection of connector to be injected as the input signal for band-stop filter
2
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=177
Type: L2
P052 = 3
P051 = 40
Offline
Speed controller droop
P630
*
Source for influencing quantity for speed droop
Selection of connector to be injected as the influencing quantity
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=162
Type: L2
P052 = 3
P051 = 40
Offline
Setting the speed controller I component
Function: When the binector selected in P695 switches state from log. "0" to log. "1", the I component of the speed controller is set to
the value of the connector selected in P631.
With this function it is possible, for example, to use the same signal (binector) to control controller enabling commands and
setting of the I component.
P631
*
Source for setting value for speed controller integrator
Selection of connector to be injected as the setting value for the I
component
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline