02.00 Parameter list
SIEMENS AG 6RX1700-0AD76 11-75
SIMOREG DC Master Operating Instructions
PNU Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
r812 Receive data on G-SST2
When USS protocol (P790=2) is selected:
Display of data received via USS interface 2
i001: Display process data word 1
...
i016 Display process data word 16
i017: Display parameter data word 1
...
i020: Display parameter data word 4
When peer-to-peer (P790=5) is selected:
Display of data received via peer-to-peer interface 2
i001: Receive data word 1
...
i005 Receive data word 5
i006: Not used
...
i020 Not used
0000 to FFFF H
1
Ind: 20
Type: L2
P052 = 3
r813 Transmit data on G-SST2
When USS protocol (P790=2) is selected:
Display of data transmitted via USS interface 2
i001: Display process data word 1
...
i016 Display process data word 16
i017: Display parameter data word 1
...
i020: Display parameter data word 4
When peer-to-peer (P790=5) is selected:
Display of data transmitted via peer-to-peer interface 2
i001: Transmit data word 1
...
i005 Transmit data word 5
i006: Not used
...
i020 Not used
0000 to FFFF H
1
Ind: 20
Type: L2
P052 = 3
r814 Receive data on G-SST3
When USS protocol (P800=2) is selected:
Display of data received via USS interface 3
i001: Display process data word 1
...
i016 Display process data word 16
i017: Display parameter data word 1
...
i020: Display parameter data word 4
When peer-to-peer (P800=5) is selected:
Display of data received via peer-to-peer interface 3
i001: Receive data word 1
...
i005 Receive data word 5
i006: Not used
...
i020 Not used
0000 to FFFF H
1
Ind: 20
Type: L2
P052 = 3