02.00 Parameter list
SIEMENS AG 6RX1700-0AD76 11-91
SIMOREG DC Master Operating Instructions
PNU Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
U146
(2146)
*
S00
Operands for 2nd divider (result = K9146) FB 46
Operands for 5th divider (result = K9143) FB 43
0 = Connector K0000
1 = Connector K0001
etc.
All connector
numbers
1
Ind:
2
[up to
SW1.7]
4
[SW 1.8 and
later]
FS=1
Type: L2
P052 = 3
P051 = 40
off-line
U147
(2147)
*
S00
Operands for 3rd divider (result = K9147) FB 47
Operands for 6th divider (result = K9144) FB 44
0 = Connector K0000
1 = Connector K0001
etc.
All connector
numbers
1
Ind:
2
[up to
SW1.7]
4
[SW 1.8 and
later]
FS=1
Type: L2
P052 = 3
P051 = 40
off-line
Multiplier
The two operands (x1, x2) for each multiplier are selected via 2 indices of the parameter each:
Index i001 = x1, Index i002 = x2
Index i003 = x1, Index i004 = x2 [SW 1.8 and later]
Index i005 = x1, Index i006 = x2 [SW 1.8 and later]
Formula:
y
xx
=
12
100%
y is limited to -200.00 to +199.99% and applied to the connector stated.
U150
(2150)
*
S00
Operands for 1st multiplier (result = K9150) FB 50
Operands for 5th multiplier (result = K9430) FB 290
Operands for 9th multiplier (result = K9431) FB 291
0 = Connector K0000
1 = Connector K0001
etc.
All connector
numbers
1
Ind:
2
[up to
SW1.7]
6
[SW 1.8 and
later]
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
U151
(2151)
*
S00
Operands for 2nd multiplier (result = K9151) FB 51
Operands for 6th multiplier (result = K9432) FB 292
Operands for 10th multiplier (result = K9433) FB 293
0 = Connector K0000
1 = Connector K0001
etc.
All connector
numbers
1
Ind:
2
[up to
SW1.7]
6
[SW 1.8 and
later]
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
U152
(2152)
*
S00
Operands for 3rd multiplier (result = K9152) FB 52
Operands for 7thmultiplier (result = K9434) FB 294
Operands for 11th multiplier (result = K9435) FB 295
0 = Connector K0000
1 = Connector K0001
etc.
All connector
numbers
1
Ind:
2
[up to
SW1.7]
6
[SW 1.8 and
later]
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
U153
(2153)
*
S00
Operands for 4th multiplier (result = K9153) FB 53
Operands for 8the multiplier (result = K9436) FB 296
Operands for 12th multiplier (result = K9437) FB 297
0 = Connector K0000
1 = Connector K0001
etc.
All connector
numbers
1
Ind:
2
[up to
SW1.7]
6
[SW 1.8 and
later]
FS=0
Type: L2
P052 = 3
P051 = 40
off-line