Parameter list 02.00
11-92 SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
High-resolution multipliers/dividers
The three operands are selected via the three indices of the parameter, i.e. index i001 = x1, index i002 = x2, index i003 = x3
Equations:
xbitxx432 1 2()
=∗ ,
y
x
x
xx
x
==
∗
4
3
12
3
Applicable for division by 0 (x2=0):
When x1 > 0: y = +199.99%
When x1 = 0: y = 0.00%
When x1 < 0: y = -200.00%
y is limited to -200.00 to +199.99% and applied to the specified connector.
U155
(2155)
*
S00
Operands for 1
st
multiplier/divider (result = K9155) FB 55
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 3
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
U156
(2156)
*
S00
Operands for 2
nd
multiplier/divider (result = K9156) FB 56
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 3
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
U157
(2157)
*
S00
Operands for 3
rd
multiplier/divider (result = K9157) FB 57
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 3
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
Absolute-value generators with filtering
U160
(2160)
*
S00
Source for input quantity for 1
st
abs.-value generator with filter FB 60
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U161
(2161)
*
S00
Signal injection mode for 1
st
abs.-value generator with filter FB 60
0 Injection of signal with correct sign
1 Injection of absolute value of signal
2 Injection of signal with sign, inverted
3 Injection of absolute value of signal, inverted
0 to 3
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
U162
(2162)
S00
Filter time for 1
st
abs.-value generator with filter FB 60
0 to 10000
[ms]
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
U163
(2163)
*
S00
Source for input quantity for 2
nd
abs.-value generator with filter FB 61
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U164
(2164)
*
S00
Signal injection mode for 2
nd
abs.-value generator with filter FB 61
0 Injection of signal with correct sign
1 Injection of absolute value of signal
2 Injection of signal with sign, inverted
3 Injection of absolute value of signal, inverted
0 to 3
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
U165
(2165)
S00
Filter time for 2
nd
abs.-value generator with filter FB 61
0 to 10000
[ms]
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
U166
(2166)
*
S00
Source for input quantity for 3
rd
abs.-value generator with filter FB 62
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U167
(2167)
*
S00
Signal injection mode for 3
rd
abs.-value generator with filter FB 62
0 Injection of signal with correct sign
1 Injection of absolute value of signal
2 Injection of signal with sign, inverted
3 Injection of absolute value of signal, inverted
0 to 3
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
U168
(2168)
S00
Filter time for 3
rd
abs.-value generator with filter FB 62
0 to 10000
[ms]
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline