02.00 Parameter list
SIEMENS AG 6RX1700-0AD76 11-105
SIMOREG DC Master Operating Instructions
PNU Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
Characteristic block 3 (Output = K9231) FB 108
Characteristic block 8 (Output = K9414) [SW1.8 and later] FB 284
Characteristic block 9 (Output = K9415) [SW1.8 and later] FB 285
U287
(2287)
*
S00
Source for input quantity
0 = Connector K0000
1 = Connector K0001
etc.
up to SW 1.7:
Selected connector = input quantity for FB108
SW 1.8 and later:
i001 Input quantity for FB108
i002 Input quantity for FB284
i003 Input quantity for FB285
All connector
numbers
1
Ind:
None
[up to SW
1.7]
3
[SW 1.8 and
later]
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
U288
(2288)
S00
x values
i001 1st characteristic point for FB108
i002 2nd characteristic point for FB108
...
i010 10th characteristic point for FB108
SW 1.8 and later:
i011 1st characteristic point for FB284
i012 2nd characteristic point for FB284
...
i020 10th characteristic point for FB284
i021 1st characteristic point for FB285
i022 2nd characteristic point for FB285
...
i030 10th characteristic point for FB285
-200.00 to 199.99
[%]
0.01
Ind:
10
[up to SW
1.7]
30
[SW 1.8 and
later]
FS=0.00
Type: I2
P052 = 3
P051 = 40
on-line
U289
(2289)
S00
y values
i001 1st characteristic point for FB108
i002 2nd characteristic point for FB108
...
i010 10th characteristic point for FB108
SW 1.8 and later:
i011 1st characteristic point for FB284
i012 2nd characteristic point for FB284
...
i020 10th characteristic point for FB284
i021 1st characteristic point for FB285
i022 2nd characteristic point for FB285
...
i030 10th characteristic point for FB285
-200.00 to 199.99
[%]
0.01
Ind:
10
[up to SW
1.7]
30
[SW 1.8 and
later]
FS=0.00
Type: I2
P052 = 3
P051 = 40
on-line
Dead zones
The component of the input quantity (x) whose absolute value exceeds the threshold for the dead zone is applied to the output (y).
Dead zone 1 (output = K9232)
U290
(2290)
*
S00
Source for input quantity FB 109
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U291
(2291)
S00
Dead zone FB 109
0.00 to 100.00
[%]
0.01
Ind: None
FS=0.00
Type: O2
P052 = 3
P051 = 40
Online
Dead zone 2 (output = K9233)
U292
(2292)
*
S00
Source for input quantity FB 110
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline