Parameter list 02.00
11-134 SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
U759
(2759)
*
Source for selection of sign reversal at [SW 1.5 and later]
analog inputs on EB1
Selection of binector to control sign reversal at the analog input ("1" state
= reverse sign)
0 = binector B0000
1 = binector B0001
etc.
i001: AI1 of the first EB1
i002: AI2 of the first EB1
i003: AI3 of the first EB1
i004: AI1 of the second EB1
i005: AI2 of the second EB1
i006: AI3 of the second EB1
All binector numbers
1
Ind: 6
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U760
(2760)
*
Filtering time for analog inputs on EB1 [SW 1.5 and later]
Note: Hardware filtering of approximately 0.2 ms is applied as standard
i001: AI1 of the first EB1
i002: AI2 of the first EB1
i003: AI3 of the first EB1
i004: AI1 of the second EB1
i005: AI2 of the second EB1
i006: AI3 of the second EB1
0 to 10000
[ms]
1ms
Ind: 6
FS=0
Type: O2
P052 = 3
P051 = 40
Online
U761
(2761)
*
Source for enabling of analog inputs on EB1 [SW 1.5 and later]
Selection of binector to control enabling of the analog input ("1" state =
enabled)
0 = binector B0000
1 = binector B0001
etc.
i001: AI1 of the first EB1
i002: AI2 of the first EB1
i003: AI3 of the first EB1
i004: AI1 of the second EB1
i005: AI2 of the second EB1
i006: AI3 of the second EB1
All binector numbers
1
Ind: 6
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
n762
(2762)
Display of analog inputs on EB1 [SW 1.5 and later]
i001: AI1 of the first EB1
i002: AI2 of the first EB1
i003: AI3 of the first EB1
i004: AI1 of the second EB1
i005: AI2 of the second EB1
i006: AI3 of the second EB1
-200.0 to 199.99
[%]
0.01%
Ind: 6
Type: I2
P052 = 3
U763
(2763)
*
Source for output value at analog outputs on EB1 [SW 1.5 and later]
Selection of connector whose value must be output at the analog output
0 = connector K0000
1 = connector K0001
etc.
i001: AO1 of the first EB1
i002: AO2 of the first EB1
i003: AO1 of the second EB1
i004: AO2 of the second EB1
All connector
numbers
1
Ind: 4
FS=0
Type: L2
P052 = 3
P051 = 40
Online
U764
(2764)
*
Mode of signal injection at analog outputs on EB1 [SW 1.5 and later]
0 = Injection of signal with sign
1 = Injection of absolute value of signal
2 = Injection of signal with sign, inverted
3 = Injection of absolute value of signal, inverted
i001: AO1 of the first EB1
i002: AO2 of the first EB1
i003: AO1 of the second EB1
i004: AO2 of the second EB1
0 to 3
1
Ind: 4
FS=0
Type: O2
P052 = 3
P051 = 40
Online