02.00 Connectors and binectors
SIEMENS AG 6RX1700-0AD76 12-7
SIMOREG DC Master Operating Instructions
Connector Description Normalization Function
diag., Sheet
4-step master switch [SW 1.7 and later]
K0510
Setpoint of the 4-step master switch
16384
=
100%
G125
General connectors
K0800
Operating status (code number) with one decimal place
K0810
Limiting bits
K0900
Optimization run, setpoint 0
K0901
Optimization run, setpoint 1
K0902
Optimization run, setpoint 2
K0903
Optimization run, setpoint 3
K0904
Optimization run, setpoint 4
K0960
Time interval between averaged line synchronization time reference point
and "unfiltered" zero crossing of scanned and software-filtered line voltage
in 1.334 µs (when P152 = 1 to 20)
1
=
1,334 µs
K0970
Positive line zero crossing of phase U-V (as T1 instant)
K0971
Negative line zero crossing of phase W-U (as T1 instant)
K0972
Positive line zero crossing of phase V-W (as T1 instant)
K0973
Negative line zero crossing of phase U-V (as T1 instant)
K0974
Positive line zero crossing of phase W-U (as T1 instant)
K0975
Negative line zero crossing of phase V-W (as T1 instant)
K0976
Positive line zero crossing, field supply
K0977
Negative line zero crossing, field supply
K0984
Last line zero crossing used (as T1 instant) (field)
K0985
Field firing instant (as T1 instant)
K0986
Last line zero crossing used (as T1 instant) (armature)
K0987
Armature firing instant (as T1 instant)
K0988
Firing pulse cycle time (time difference between current and previous
armature firing instant) in T1 increments of 1.334 µs each