Connectors and binectors 02.00
12-8 SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
Connector Description Normalization Function
diag., Sheet
K0989
Information about torque direction and firing angle
Nibble 0 .. Torque direction
0 = M0 (--)
1 = MI
2 = MII
9 = The master waits in M0 until all slaves have reached the
RUN state
Nibble 1 .. Code number for firing angle
1 = Firing angle requested by current controller+precontrol
implemented
2 = Firing angle requested by current controller+precontrol
was > P151. It has been implemented or limited to 165 °
3 = Alpha-W pulse at 165°
4 = Alpha-W pulse at P151 angle setting
5 = Firing angle requested by current controller+precontrol
could not be implemented due to strong pulse compression
6 = Slave connected in parallel could not adapt its computing
cycle to the firing angle of the paralleling master
7 = No firing angle received from paralleling master
8 = The cycle time received from the paralleling master is too
long
9 = The firing angle of the paralleling master has been
implemented
Nibble 2 .. Code number for requested torque direction
0: Not RUN ( ≥ o1.0)
1: Torque direction acc. to current setpoint K119 (==> M0, MI, MII)
2: Wait for enable from parallel drive [acc. to P165] (==> M0)
3: Firing angle of > 165 degrees requested (==> M0)
4: Additional wait time in auto-reversing stage (==> M0)
5: Output pulse at 165 degrees in old torque direction
(==> MI, MII)
6: Output Alpha_W pulse (acc. to P151) in the old torque direction
(==> MI, MII)
7: Torque direction request during short-circuit test of thyristor check
function (==> MI)
8: Torque direction request during open circuit test of thyristor check
function (==> M0, MI, MII)
9: The selected thyristor pair is disabled during thyristor check (==> M0)
A: No meaning
B: Torque direction of paralleling is being implemented
(==> M0, MI, MII)
C: Simulation operation (==> MI, MII)
D: The command “Fire all thyristors simultaneously“ is being executed
(see also under P0176)
K0990
Current total processor capacity utilization (C167)
K0991
Projected total processor capacity utilization (C167) for maximum line
frequency (65 Hz)
K0992
Total processor capacity (C167) currently utilized by background routines
K0993
Total processor capacity (C167) currently utilized by routines synchronized
with field firing pulses
K0994
Total processor capacity (C167) currently utilized by routines synchronized
with armature firing pulses
Serial interface 1 (USS1 on G-SST1)
K2001
USS1 receive data, word 1
1
=
∧
1
G170
K2002
USS1 receive data, word 2
1
=
∧
1
G170
K2003
USS1 receive data, word 3
1
=
∧
1
G170
K2004
USS1 receive data, word 4
1
=
∧
1
G170
K2005
USS1 receive data, word 5
1
=
∧
1
G170
K2006
USS1 receive data, word 6
1
=
∧
1
G170
K2007
USS1 receive data, word 7
1
=
∧
1
G170
K2008
USS1 receive data, word 8
1
=
∧
1
G170