Maintenance 02.00
13-4 SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
Replacement of fan on 400A to 850A converters
4U1
4V1
4W1
PE
1
2
The fan is mounted on the underside of the converter.
• Remove connector
a .
• Use a T20 screwdriver to undo the two Torx screws
s .
• Lift the fan using the fixing straps and pull out downwards.
• Install the new fan in the reverse order.