02.00 Maintenance
SIEMENS AG 6RX1700-0AD76 13-5
SIMOREG DC Master Operating Instructions
Replacement of fan on 900A to 1200A converters
3
1
2
The fan is mounted on top of the converter.
• Remove connector
a .
• Undo the M6 Torx screws
s.
• Undo the M6 hexagonal nuts
d.
• Pull fan upwards out of its guideway and then forwards to remove. Take care to protect the field
module mounted on the left (risk of mechanical damage!).
• Install the new fan in the reverse order.