Parameter list 02.00
11-52 SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
P606
*
Source for variable negative torque limit
Torque limitation:
Selection of connectors to be injected as the variable negative torque
limit
(100% of connector value corresponds to negative system torque limit
obtained with settings I
a
=P172 and I
f
= P102)
0 = connector K0000
...
8 = connector K0008
9 = value as set in parameter P605 ∗ (−1)
10 = connector K0010
etc.
All connector
numbers
1
Ind: 4
FS=9
Type: L2
P052 = 3
P051 = 40
Offline
P607
*
BDS
Source for torque setpoint for master drive
Torque limitation:
Selection of connector to be injected as the torque setpoint for a master
drive
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 2
FS=148
Type: L2
P052 = 3
P051 = 40
Offline
Speed controller
P609
*
Source for actual speed controller value
Selection of connector to be injected as the actual speed controller value
when P083=4
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
Setting values for configuring of closed-loop field and EMF control
P610
*
Source for gating unit input (field)
Selection of connector to be applied to the gating unit input (field)
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=252
Type: L2
P052 = 3
P051 = 40
Offline
P611
*
Source for field current controller setpoint
Limitation at EMF controller output:
Selection of connectors to be injected as the field current controller
setpoint. The connectors selected in the four indices are added.
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 4
FS=
i001: 277
i002: 0
i003: 0
i004: 0
Type: L2
P052 = 3
P051 = 40
Offline
P612
*
Source for actual field current controller value
Selection of connector to be injected as the actual field current controller
value
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=266
Type: L2
P052 = 3
P051 = 40
Offline
P613
*
Source for variable field current setpoint upper limit
Limitation at EMF controller output
Selection of connector to be injected as the variable field current setpoint
upper limit
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 4
FS=1
Type: L2
P052 = 3
P051 = 40
Offline