Getting Started
100 A5E37208904-003, 04/2017
Par. No.
Name
Min
Max
Factory
Setting
Unit
Data
type
Effective
Can be
changed
p8923[0...
3]
PROFIdrive: Subnet
mask of station
0 255 0 - U8 IM T, U
Description:
Sets the subnet mask for the onboard PROFINET interface on the Control Unit.
The active subnet mask is displayed in r8933.
Note:
The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.
p8925 PROFIdrive: Interface
configuration
0 3 0 - U8 IM T, U
Description:
Setting to activate the interface configuration for the onboard PROFINET interface on the Control
Unit.
p8925 is automatically set to 0 at the end of the operation.
p8925 = 0: No function
p8925 = 2: Save and activate configuration
The interface configuration (p8920 and following) is saved and activated after the next POWER ON.
p29000 *
Motor ID
0
65535
0
-
U16
IM
T
Description:
Motor type number is printed on the motor rating plate as motor ID.
For a motor with an incremental encoder, users need to manually input the parameter value.
For a motor with an absolute encoder, the drive automatically reads the parameter value.
p29001 Reversal of motor direc-
tion
0 1 0 - I16 IM T
Description:
Reversal of motor running direction. By default, CW is the positive direction while CCW the nega-
tive direction. After changing of p29001, reference point will lost, A7461 will remind user to referencing again.
0: No reversal
1: Reverse
p29002
BOP display selection
0
4
0
-
I16
IM
T, U
Description:
Selection of BOP operating display.
0: Actual speed (default)
1: DC voltage
2: Actual torque
3: Actual position
4: Position following error
p29003
Control mode
1
2
2
-
I16
IM
T
Description:
Selection of control mode.
1: Basic positioner control mode (EPOS)
2: Speed control mode (S)
p29005
Braking resistor capacity
percentage alarm thresh-
old
1 100 100 % Float IM T
Description:
Alarm triggering threshold for the capacity of the internal braking resistor.
Alarm number: A52901
p29006
Line supply voltage
200
480
400/230
V
U16
IM
T
Description:
Nominal Line supply voltage, effective value of line to line voltage. Drive can operate within -15%
to +10% error.
For 400 V variant servo drive, the value range is 380 V to 480 V, default value is 400 V.
For 200 V variant servo drive, the value range is 200 V to 240 V, default value is 230 V.