Getting Started
A5E37208904-003, 04/2017
99
Par. No.
Name
Min
Max
Factory
Setting
Unit
Data
type
Effective
Can be
changed
p2634 EPOS fixed stop maxi-
mum following error
0 214748264
7
1000 LU U32 IM T, U
Description: Sets the following error to detect the "fixed stop reached" state.
Dependency:
Refer to: p2621
Note:
The state "fixed stop reached" is detected if the following error exceeds the theoretically calculated
following error value by p2634.
p2635 EPOS fixed stop monitor-
ing window
0 214748264
7
100 LU U32 IM T, U
Description: Sets the monitoring window of the actual position after the fixed stop is reached.
Dependency: Refer to: F07484
Note:
If, after the fixed stop is reached, the end stop shifts in either the positive or negative direction by more
than the value set here, an appropriate message is output.
p2690 MDI position fixed set-
point
-2147482648 214748264
7
0 - I32 IM T, U
Description: Sets a fixed setpoint for the position.
p2691 MDI velocity fixed set-
point
1 40000000 600 100
0 L
U/mi
n
U32 IM T, U
Description:
Sets a fixed setpoint for the speed.
p2692 MDI acceleration over-
ride, fixed setpoint
0.100 100.000 100.000 % Float IM T, U
Description: Sets a fixed setpoint for the acceleration override.
Dependency: Refer to: p2572
Note: The percentage value refers to the maximum acceleration (p2572).
p2693 MDI deceleration over-
ride, fixed setpoint
0.100 100.000 100.000 % Float IM T, U
Description: Sets a fixed setpoint for the deceleration override.
Dependency: Refer to: p2572
Note: The percentage value refers to the maximum deceleration (p2573).
p8920[0...
239]
PROFIdrive: Name of
station
- - - - U8 IM T, U
Description:
Sets the station name for the onboard PROFINET interface on the Control Unit.
The active station name is displayed in r8930.
Note:
The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.
p8921[0...
3]
PROFIdrive: IP address
of station
0 255 0 - U8 IM T, U
Description:
Sets the IP address for the onboard PROFINET interface on the Control Unit.
The active IP address is displyed in r8931.
Note:
The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.
p8922[0...
3]
PROFIdrive: Default
gateway of station
0 255 0 - U8 IM T, U
Description:
Sets the default gateway for the onboard PROFINET interface on the Control Unit.
The active default gateway is displayed in r8932.
Note:
The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.