Overview of Alarms 11/2006
NCK alarms
2-40
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
4040 Channel %1 axis identifier %2 not consistent with machine data %3
Parameters: %1 = Channel number
%2 = String: Axis identifier
%3 = String: MD identifier
%4 = There are not enough channel axes entered in the MD displayed.
Definitions: The use of the specified axis identifier in the displayed MD is not consistent the channel's axis
configuration stated in the MD 20070 AXCONF_MACHAX_USED and MD 20050
AXCONF_GEOAX_ASSIGN_TAB.
Only with active "OEM transformation" compile cycle: There are not enough channel axes entered in
the MD displayed.
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Check and correct the identifier used in
the MDs 10000 AXCONF_MACHAX_NAME_TAB, 20080 AXCONF_CHANAX_NAME_TAB and/or
20050 AXCONF_GEOAX_NAME_TAB.
Only with active "OEM transformation" compile cycle: In addition to the specified MD, check and
correct MD 24110 TRAFO_AXES_IN_1[n] of the activated OEM transformation according to the
function description.
Program
Continuation:
Switch control OFF - ON.
4045 Channel %1 conflict between machine data %2 and machine data %3
Parameters: %1 = Channel number
%2 = String: MD identifier
%3 = String: MD identifier
Definitions: Using the specified machine data %1 leads to a conflict with machine data %2.
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Correct the specified machine data.
Program
Continuation:
Switch control OFF - ON.