Overview of Alarms 11/2006
NCK alarms
 
2-62
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
 
4502 Channel %1 anachronism %2(%3) -> %4
Parameters: %1 = Channel number
%2 = String: MD identifier
%3 = String: MD identifier
%4 = String: MD identifier
Definitions: Previously, in $MC_RESET_MODE_MASK Bit4 and Bit5, the reset behavior of the 6th or 8th G 
groupe was determined. This setting is now made in $MC_GCODE_RESET_MODE.
In order to ensure compatible handling of "old" data backups, the "old" values are taken from 
$MC_RESET_MODE_MASK and entered in $MC_GCODE_RESET_MODE.
Reaction: Alarm display.
Remedy: --
Program 
Continuation:
Clear alarm with the Delete key or NC START.
4503 In TO unit, %1 H number %2 assigned more than once. H number linked 
again.
Parameters: %1 = TO unit
%2 = H number
Definitions: This error can only occur when MD $MN_MM_EXTERN_CNC_SYSTEM= 1 or 2. The Power ON 
effective machine data bit 10890, $MN_EXTERN_TOOLPROG_MODE, bit 3 has been reset. On 
reconstructing data handling after Power ON, it has been found that different edges of the same TO 
unit have the same H number. They had been linked previously. They are linked again and MD bit 
$MN_EXTERN_TOOLPROG_MODE, bit 3 is set again.
Reaction: Alarm display.
Remedy: H numbers must be assigned only once in a TO unit. Then, machine data bit 10890, 
$MN_EXTERN_TOOLPROG_MODE, bit 3 can be set = 0 and a restart can be performed.
Program 
Continuation:
Clear alarm with the Delete key or NC START.
4600 Invalid handwheel type for handwheel %1
Parameters: %1 = Handwheel number
Definitions: The handwheel type for handwheel %1 requested through machine date 
$MN_HANDWHEEL_SEGMENT is invalid.
Reaction: Interface signals are set.
Alarm display.
Remedy: Configure a valid type for the corresponding handwheel through machine date 
$MN_HANDWHEEL_SEGMENT.
Program 
Continuation:
Switch control OFF - ON.
4610 Invalid handwheel module for handwheel %1
Parameters: %1 = Handwheel module
Definitions: The handwheel module for handwheel %1 requested through machine date 
$MN_HANDWHEEL_MODULE is not available for 840D systems. An 840D system is always 
regarded as a module. For this reason, handwheels directly linked with 840D systems  
$MN_HANDWHEEL_MODULE = 1 must always be set.
Reaction: Interface signals are set.
Alarm display.
Remedy: Set machine date $MN_HANDWHEEL_MODULE = 1 for the corresponding handwheel.
Program 
Continuation:
Switch control OFF - ON.