EasyManua.ls Logo

Siemens SINUMERIK 810D - Page 701

Siemens SINUMERIK 810D
880 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SIMODRIVE alarms
11/2006 Overview of Alarms
2-701
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
300412 Error when storing a file (%1, %2)
Parameters: %1 = Error code 1
%2 = Error code 2
Definitions: An attempt to save a data block, i.e. the result of a measuring function, in the file system has failed.
Reaction: Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department. Create more space in the file system. It
is normally sufficient to delete 2 NC programs or to free 4 - 8 Kbytes of memory. If these remedies do
not work, it will be necessary to increase the number of files per directory or the size of the file system
itself. To do so, proceed as follows:
- Save all data
- Change settings of machine data
- 18280 $MM_NUM_FILES_PER_DIR
- 18320 $MM_NUM_FILES_IN_FILESYSTEM
- 18350 $MM_USER_FILE_MEM_MINIMUM
- and, if necessary, of
- 18270 $MM_NUM_SUBDIR_PER_DIR
- 18310 $MM_NUM_DIR_IN_FILESYSTEM
- Power On
- Reload saved data
Program
Continuation:
Clear alarm with the RESET key. Restart part program
300413 Error when reading a file (%1, %2)
Parameters: %1 = Error code 1
%2 = Error code 2
Definitions: An attempt to read a data block, e.g. a drive boot file, from the file system has failed. The data block
or the file system is damaged.
Reaction: Interface signals are set.
Alarm display.
Remedy: If the error occurred during power-up, i.e. it is probably connected to a drive boot file, delete all boot
files and load them back into the control from the back-up copy.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
300423 Measuring results could not be read (%1)
Parameters: %1 = Error code
Definitions: An attempt to read a measurement result has failed:
- Error code = 4: Not enough space for test result
- Error code = 16: Measurement not yet finished
Reaction: Interface signals are set.
Alarm display.
Remedy: Repeat measurement. Alter measuring time if necessary.
Program
Continuation:
Clear alarm with the RESET key. Restart part program

Other manuals for Siemens SINUMERIK 810D

Related product manuals