SIMODRIVE alarms
11/2006 Overview of Alarms
2-721
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
300706 Axis %1 drive %2 monitoring cycle time invalid
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: Monitoring cycle MD 1002: $MD_MONITOR_CYCLE_TIME is invalid.
Reaction: NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. See Drive Functions "FB/DB1".
Program
Continuation:
Switch control OFF - ON.
300707 Axis %1 drive %2 basic cycle times of axes differ
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: In a 2-axis module, the basic drive cycle for the two axes is not the same. This alarm can only occur
with OEM users who have the 611D drive without the standard NCK interface. This makes it possible
for axially different basic drive cycles to be transferred to the 611D modules.
Reaction: NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Set the same basic drive cycle for both
axes.
Program
Continuation:
Switch control OFF - ON.
300708 Axis %1 drive %2 current controller cycle times of axes differ
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The current controller cycle MD 1000: $MD_CURRCTRL_CYCLE_TIME must be identical for both
axes on 2-axis modules.
Reaction: NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. The current controller cycle MD 1000:
$MD_CURRCTRL_CYCLE_TIME must be identical for both axes on 2-axis modules.
Program
Continuation:
Switch control OFF - ON.