SIMODRIVE alarms
11/2006 Overview of Alarms
2-731
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
300731 Axis %1 drive %2 rated power less than or equal to zero
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The value in MD 1130: $MD_MOTOR_NOMINAL_POWER (rated motor power) is less than or equal
to zero.
Reaction: NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department.
For standard motors: Reset the drive (delete the bootfile) and repeat the startup.
For third-party motors: Check and, if necessary, refer to the motor data sheet to correct MD 1130:
$MD_MOTOR_NOMINAL_POWER (rated motor power).
Program
Continuation:
Switch control OFF - ON.
300732 Axis %1 drive %2 rated speed less than or equal to zero
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The value in MD 1400: $MD_MOTOR_RATED_SPEED (rated motor speed) is less than or equal to
zero.
Reaction: NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department.
For standard motors: Reset the drive (delete the bootfile) and repeat the startup.
For third-party motors: Check and, if necessary, refer to the motor data sheet to correct MD 1400:
$MD_MOTOR_RATED_SPEED (rated motor speed).
Program
Continuation:
Switch control OFF - ON.