Overview of Alarms 11/2006
SIMODRIVE alarms
2-798
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
311711 Axis %1 drive %2 transmission length SSI motor measuring system
invalid
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The configuration of the motor measuring system for an SSI encoder is incorrect: MD 5028
$MD_NO_TRANSMISSION_BITS (SSI frame length) is smaller than the number of all parameterized
bits in MD 5021 $MD_ENC_ABS_TURNS_MOTOR (multiturn), MD 5022
$MD_ENC_ABS_RESOL_MOTOR (singleturn) and MD 5027 $MD_ENC_CONFIG bit 14 (alarm bit)
and MD 5027 $MD_ENC_CONFIG bit 12 (parity bit).
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Set parameters correctly for all associated machine data:
- MD 5028 $MD_NO_TRANSMISSION_BITS (SSI frame length): number of bits in an SSI protocol,
including all bits, such as alarm bit/parity bit
- MD 5021 $MD_ENC_ABS_TURNS_MOTOR (ultiturn): number of resolvable revolutions
- MD 5022 $MD_ENC_ABS_RESOL_MOTOR (singleturn): number of increments per revolution
- MD 5027.Bit 12 $MD_ENC_CONFIG.Bit 12: parity bit
- MD 5027.Bit 14 $MD_ENC_CONFIG.Bit 14: alarm bit
Example:
SSI encoder with 25 bits message frame length, 12 bits multiturn, 12 bits singleturn, one alarm bit:
- $MD_NO_TRANSMISSION_BITS = 25
- $MD_ENC_ABS_TURNS_MOTOR = 4096
- $MD_ENC_ABS_RESOL_MOTOR = 4096
- $MD_ENC_CONFIG.Bit 14 = 1
- $MD_ENC_CONFIG.Bit 12 = 0
Program
Continuation:
Switch control OFF - ON.
311712 Axis %1 drive %2 multiturn SSI motor measuring system invalid
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The configuration of a linear SSI motor measuring system is incorrect: A linear measuring system
cannot have any multiturn information.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Set MD 5021 $MD_ENC_ABS_TURN_MOTOR (number of representable revolutions) to 0.
Program
Continuation:
Switch control OFF - ON.

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?

Siemens SINUMERIK 810D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 810D
CategoryControl Unit
LanguageEnglish

Related product manuals