1 Alarms 11.02
1-14
Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
1000 System error %1
Parameters: %1 = System error number
Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the trans-
ferred error number, provide information on the cause and location of the error.
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Make a note of the error text and contact Siemens A&D MC, Hotline
• Phone: 0180-5050-222 (Germany)
• Fax: 0180-5050-223
• Phone: ++49-(0)180-5050-222 (International)
• Fax: ++49-(0)180-5050-223
• email techsupport@ad.siemens.de
Program Continuation: Switch control OFF - ON.
1001 System error %1
Parameters: %1 = System error number
Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the trans-
ferred error number, provide information on the cause and location of the error.
Reactions: - Alarm display.
- Interface signals are set.
- Mode group not ready.
- Channel not ready.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Program Continuation: Clear alarm with the RESET key in all channels of this mode group. Restart part program.
1002 System error %1
Parameters: %1 = System error number
Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the trans-
ferred error number, provide information on the cause and location of the error.
Reactions: - Alarm display.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Program Continuation: Clear alarm with the Delete key or NC START.
1003 Alarm pointer for this self-clearing alarm %1 is zero
Parameters: %1 = Incorrect alarm number
Definitions: The address (zero pointer) used by the compile cycle manufacturer or by the operating
system for self-clearing alarms is not allowed in the system.
Reactions: - Alarm display.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Check setCCAlarm/setAlarm (...) call.
Program Continuation: Clear alarm with the Delete key or NC START.