11.02 1 Alarms
1004 Alarm reaction to NCK alarm incorrectly configured
Parameters: %1 = Incorrect alarm number
Definitions: The alarm reaction configured by the operating system or the compile cycles manufac-
turer is incorrect.
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Channel not ready.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Change alarm reaction
Program Continuation: Switch control OFF - ON.
1005 Operating system error %1 parameter %2 %3 %4
Parameters: %1 = Operating system error number
%2 = Operating system error parameter 1
%3 = Operating system error parameter 2
%4 = Operating system error parameter 3
Definitions: This alarm indicates that the operating system has detected a serious error.
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Program Continuation: Switch control OFF - ON.
1010 Channel %1 system error %2 action %3
Parameters: %1 = Channel number
%2 = System error number
%3 = Action number/action name
Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the trans-
ferred error number, provide information on the cause and location of the error.
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- Interpreter stop
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Program Continuation: Switch control OFF - ON.
1011 Channel %1 %3 %4 system error %2
Parameters: %1 = Channel number
%2 = System error number
%3 = Optional parameter: Block number, label