Overview of Alarms 11/2006
NCK alarms
2-558
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61557 Channel %1 block %2: Impossible chamfer and radius of right edge of
wheel
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: CYCLE432
Remedy: Check values in grinding wheel data
61558 Channel %1 block %2: Chamfer / radius + shoulder height are less than
the retraction height of the left edge of the grinding wheel
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: CYCLE432
Remedy: Check values in grinding wheel data
61559 Channel %1 block %2: Chamfer / radius + shoulder height are less than
the retraction height of the right edge of the grinding wheel
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: CYCLE432
Remedy: Check values in grinding wheel data
61601 Channel %1 block %2: Finished part diameter too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The programmed radius of the machined part is too small. Alarm triggered by following cycles:
CYCLE94, CYCLE96.
Remedy: Check parameter SPD or DIATH.
61602 Channel %1 block %2: Tool width incorrectly defined
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Plunge cutter is larger than the programmed groove width. Alarm triggered by following cycle:
CYCLE93.
Remedy: Check tool or change program.
61603 Channel %1 block %2: Recess type incorrectly defined
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Radii/chamfers at the groove base do not match the groove width. Face groove on a contour element
running parallel to the longitudinal axis is not possible. Alarm triggered by following cycle: CYCLE93.
Remedy: Check parameter VARI.