EasyManuals Logo

Siemens SINUMERIK 840D Diagnostic Manual

Siemens SINUMERIK 840D
880 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #604 background imageLoading...
Page #604 background image
Overview of Alarms 11/2006
NCK alarms
2-604
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
75604 Channel %1 RESU: Return traveling not possible, error code %2
Parameters: %1 = Channel number
%2 = Error code
Definitions: Return traveling is not possible, as the following error was detected:
Error code = 1 : The current reverse block for return traveling is likely to be a block of cc_resu_ini.spf
or cc_resu_end.spf programmed with a block number. It is impermissible to program block numbers
in the subroutines cc_resu_ini.spf and cc_resu_end.spf, as they have an internal meaning.
Error code = 2 : Unable to create cc_resu.mpf, as DRAM is insufficient.
Error code = 4 : The selected continuation block is likely to be a block of cc_resu_ini.spf or
cc_resu_end.spf programmed with block number. It is impermissible to program block numbers in the
subroutines cc_resu_ini.spf and cc_resu_end.spf, as they have an internal meaning.
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Error code = 1 or 4 : Remove all block numbers from cc_resu_ini.spf and cc_resu_end.spf and their
subroutines.
Error code = 2 : Assign a higher value to machine date $MN_MM_DRAM_FILE_MEM_SIZE.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
75605 Channel %1 RESU: internal error, error code %2
Parameters: %1 = Channel number
%2 = Error code
Definitions: With this alarm, RESU-internal error states are displayed which, together with the transferred error
number, provide information on the error cause and error location.
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: If this error occurs, please contact us on the SINUMERIK Hotline of the SIEMENS AG, specifying the
error number.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
75606 Channel %1 RESU: retraceable contour was shortened
Parameters: %1 = Channel number
Definitions: The block search buffer is full. Therefore the retraceable contour had to be shortened.
Reaction: Alarm display.
Remedy: This alarm has no effect on the current machining. If the alarm continues to occur frequently, the
reason should be eliminated: adjust machine data $MC_RESU_RING_BUFFER_SIZE,
$MC_RESU_SHARE_OF_CC_HEAP_MEM and $MC_MM_NUM_CC_HEAP_MEM.
Program
Continuation:
Clear alarm with the Delete key or NC START.
75607 Channel %1 RESU: resynchronisation not possible
Parameters: %1 = Channel number
Definitions: The block search triggered by the compile cycle has been terminated with an error. It can have the
following cause: The control is not in the correct operating mode, e.g. in JOG_ AUTO instead of in
AUTO.
Reaction: Interface signals are set.
Alarm display.
Remedy: Switch the control to the AUTO operating mode and restart resynchronisation.
Program
Continuation:
Clear alarm with the Delete key or NC START.

Other manuals for Siemens SINUMERIK 840D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D and is the answer not in the manual?

Siemens SINUMERIK 840D Specifications

General IconGeneral
SeriesSINUMERIK 840D
AxesUp to 31
ChannelsUp to 10
Operating SystemWindows-based
Power Supply24 V DC
Control Unit TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
InterpolationSpline
PLCIntegrated PLC
Data StorageCompactFlash, USB

Related product manuals