HMI alarms
11/2006 Overview of Alarms
2-667
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
112502 Not enough memory space%nAbort in line %1.
Parameters: %1 = Line number
Definitions: The program cannot interpret a program block with contour programming. Contour not in the directory.
Program is not loaded.
The program cannot interpret a program block with contour programming. Contour not in the directory.
Reaction: Alarm display.
Remedy: Load contour into the directory.
Program
Continuation:
Internal
112503 ShopMill: %1
Definitions: A system error has occurred.
Reaction: Alarm display.
Remedy: Please contact the hotline of Siemens AG, A&D MC and provide with the error message.
Program
Continuation:
Clear alarm with the Delete key or NC START.
112504 File does not exist or is faulty%n%1
Parameters: %1 = File name
Definitions: The program cannot interpret a program block with contour programming.
Contour not in the directory.
Reaction: NC Start disable in this channel.
Alarm display.
Remedy: Load contour into the directory.
Program
Continuation:
Internal
112505 Error on interpreting contour:%n%1
Parameters: %1 = Contour name
Definitions: Contour is faulty.
Reaction: NC Start disable in this channel.
Alarm display.
Remedy: Check the contour's machining sequence.
Program
Continuation:
Internal
112506 Maximum number of contour elements exceeded:%n%1
Definitions: The maximum permissible number of 50 contour elements was exceeded when interpreting the
machining sequence of a contour.
Reaction: Alarm display.
Remedy: Check the contour's machining sequence and, if necessary, edit it.
Program
Continuation:
Internal
112541 Program cannot be interpreted
Definitions: The program cannot be interpreted as a ShopMill program during loading, as the program header is
missing.
Reaction: NC Start disable in this channel.
Alarm display.
Remedy: --
Program
Continuation:
Internal